6 Magellan
®
8500
Volume/Tone Push Button
The Volume/Tone Push Button also performs multiple functions depending upon the
duration of time it is pressed:
Table 4. Volume/Tone Push Button Functions
PRESS
DURATION
FUNCTION COMMENT
Momentary (when
scanner is asleep)
Wakes scanner from
Sleep Mode
Alternatively, the scanner can be awakened by:
- Moving an object through the scan zone.
- A weight change on the scale.
- Scanning with an attached auxiliary scanner.
Momentary (when
scanner is awake)
Increments volume
Press the push button momentarily to increase
speaker volume. When the loudest volume is
reached, a repeated press of the push button cycles
volume back to the lowest setting, then volume
increases on subsequent press(es). Five volume lev-
els are available.
Hold, then release
when the beeper
sounds
Increments tone
Press the push button for approximately 2 seconds,
then release. Each time this is done, the beeper will
sound at one of three tones. Stop when the desired
tone (high, medium or low) is sounded.
4 Seconds
Scanner Diagnostics
Mode
a
a. By standard default, this function is normally disabled to prevent accidental activation
by users.
This mode allows system support personnel to trou-
bleshoot problems with the scanner. Generally diag-
nostics are initiated after noting a Field Replaceable
Unit (FRU) Warning (see Table 1). Cycle power to
exit Scanner Diagnostics Mode.
8 Seconds
Resets Scanner
b
b. Users should not perform scanner resets except under the direction of trained sys-
tems support personnel.
Only system support personnel should perform a
reset.