PSC QuickScan 1000 User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
Installation
How to Scan
Reference Figure 3 and follow these tips to get the best scanning results:
1. The scanner must be pointed at a slight angle in relation to the
bar code (Not perpendicular to the bar code.)
2. The laser beam must cross the entire bar code. (The scanner
cannot correctly read a bar code if the entire bar code is not
scanned.)
Figure 3
Troubleshooting
If the scanner is not operating properly, the following checks should be
performed: Reference Figures 4 and 5.
1. Since the scanner can receive its power from the host computer
(Power Off the Terminal—P.O.T.) or an external power supply, it
will not operate without the system power on (Figure 4a) or if the
external power supply has failed.
2. Check that the bar code labels are of sufficient quality to be
recognized by the scanner (Figure 4b). Wrinkled, smudged, or
torn bar codes can cause the scanner to not read at all. If you
suspect that label quality is a problem, scan a known good bar
code to check the scanner's read operation. Is the scanner
programmed to read the bar code symbology desired? Consult the
QuickScan 1000™ Scanner Programming Guide (P/N R44-2018)
for more information (Figure 4c).*
3. Ensure that the scanner's interface type is compatible with the host
terminal by consulting your POS system manual and/or the
QuickScan 1000 Scanner Programming Guide (P/N R44-2018).
4. Verify that the interface (I/F) cable is securely attached to the
scanner handle (Figure 4d). If you need to disconnect/reconnect
the I/F cable from the scanner, insert the tip of a paper clip into the
cable release hole shown in Figure 5. Push the clip in to depress
the connector latch and release the cable. To reconnect the cable,
orient the cable with its connector inside the scanner handle and
press it in firmly to seat and latch securely in place.
5. Verify that the interface) cable is securely attached to the host
(Figure 4e). Consult your technical support manager or refer to
your host system manual to verify the proper connection for the
scanner.
6. If an external power supply is used, exchange the power supply
with a known good power supply (Figure 4g).
If the scanner receives power from the host (P.O.T.), connect the
scanner to a known good host.
If the scanner still does not function properly, contact your local supplier
or PSC Customer Support Services.
1-(800)-547-2507 (US only) or
(541) 683-5700 (outside US)
* This Programming Guide is available on the
internet at www.pscnet.com.
CE Declaration of Conformity
PSC hereby declares that the equipment specified below has been
tested and found compliant to the following Directives and
Standards:
Directives: EMC 89/336/EEC
Low Voltage 73/23/EEC
Standards: EN55022-B EN60825
EN50082-1 EN60950
Equipment Type:Bar code Scanning Equipment
Products: Model QuickScan 1000™
Brad West
Vice President
Quality and Process
Management
PSC, Inc.
959 Terry Street
Eugene, OR 97402
U.S.A.
Peter Lomax
Vice President
Europe, Middle East & Africa
PSC Bar Code Ltd.
Axis 3, Rhodes Way
Watford
Hertfordshire WD24 4TR
UK
Figure 4
Figure 1
TROUBLESHOOTING - CONT.
Figure 5
Installation - cont.
Figure 2
Refer to Figures 1 and 2, and follow these steps to install the scanner:
1. Turn the host power off (consult the manual for your host
terminal power-off procedures). See Figure 2a.
2. Connect the interface (I/F) cable to the proper port on the Host
terminal (Figure 2b).
If your scanner will receive Power Off the Terminal, skip to step 5.
3. Connect the power cord from the AC/DC adapter at the I/F
connector (Figure 2c).
4. Connect the AC/DC adapter at the wall outlet (Figure 2d).
5. Turn host power on. (Consult the manual for your host
terminal for power-on procedures.)
6. Verify operation--point the laser spot at a sample bar code to
scan it and confirm that the scanner reads by beeping and/or
sending the data to the host terminal.
7. If your installation includes a QS1000™ scanner stand and you
wish to attach it to a countertop, unscrew the gooseneck/cradle
assembly from the base as shown in Figure 1a. Secure the
mount plate to the counter with four screws, then reassemble
the stand in place. The scanner rests in the cradle as shown in
Figure 1b.
When the scanner is powered on, its LaserSense™ feature
automatically detects when you move a bar code label into
range and clearly shows you where the bar code should be
placed by projecting a laser marker spot.
Page view 1
1 2

Comments to this Manuals

No comments