Programming Guide 111
Configuring
the Code 93
Options
Use these special bar codes to configure the Code 93 options.
Minimum Label
Length
1. Identify the minimum length setting you want to make. The
selectable range is 01 to 50
1
characters.
2. Scan the SET bar code.
3. Scan the SET MINIMUM LABEL LENGTH bar code.
4. Set the minimum label length by scanning the applicable digits
from page 112. The range is 01 to 50
1
characters. Return to this
page and go to step five.
5. Scan the END bar code.
1. For this symbology, the scanner will decode up to 50 characters, but the actual length read
will vary depending upon interface type, and bar code physical size and quality. The IBM
POS interface is limited to 32 character labels. Code 93 bar codes containing one or more
shift characters can also limit the amount of characters that will be decoded (in these cir-
cumstances, the scanner will decode at least 39 data characters).
NOTE
If you are setting a label length less than ten, you
must scan a zero digit first and then the length
digit (e.g., 04, 06, 08).
SET ------------------------------------------
Set Minimum Label
Length ---------
END ------------------------------------------