PSC 2200VS Specifications Page 291

  • Download
  • Add to my manuals
  • Print
  • Page
    / 382
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 290
Codabar Enable
Product Reference Guide 5-243
Codabar Minimum Label Length
This feature specifies the minimum allowable length of a Codabar label.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET CODABAR MINIMUM LABEL LENGTH
below. You’ll need to cover any unused bar codes on this and the fac-
ing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired minimum label length. The selectable range for
this option is 03 to 50. Pad all single digit numbers with a leading
zero to yield a two-digit entry (03-50).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET CODABAR MINIMUM LABEL LENGTH
NOTE
Length in this case includes start, stop or check and data charac-
ters, but does not include full ASCII shift characters. This feature
applies when Codabar Length Control is set to variable-length
decoding.
Minimum label length should be less than or equal to maximum
label length.