Programming
5-32 Magellan
®
2200VS/2200VSΩ and 2300HS/2300HSΩ
EAS Active State
Specifies the active state polarity of EAS (Electronic Article Surveillance);
the inactive state is its opposite polarity. EAS output goes active during the
good read of a bar code, allowing the EAS device to deactivate a tag on the
product.
To set the EAS Active State:
1. Scan the SWITCH bar code.
2. Scan bar code below representing the desired setting. You’ll need to
cover any unused bar codes on this and the facing page to ensure
that the scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
EAS ACTIVE STATE = ACTIVE LOW
EAS ACTIVE STATE = ACTIVE HIGH