PSC Scanners User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 66
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
Product Reference Guide 9
Momentary:
The trigger button acts as a switch. Pressing the button
activates scanning and releasing the button stops scanning.
Alternate:
The trigger button acts as a toggle switch. Pressing the
button activates or stops scanning.
Timeout off:
The trigger button must be pressed to activate scanning,
and the QS2500 stops scanning when no code is decoded after the
standby duration has elapsed.
Continue:
The QS2500 always keeps reading, and it does not matter
whether the trigger button is pressed or the standby duration has
elapsed.
Test only:
The QS2500 always keeps a constant reading, and same-
label reading is allowed without double confirmation. The feature
can test the performance of the QS2500 for reading speed and
sensitivity.
Standby Duration:
A timeout duration of 1 to 99 seconds can be set. It is
effective only when the CCD scanning mode is operated in timeout-off
mode and good-read off mode.
Same Bar Code Delay Time:
If the bar code has been scanned twice, then
only the first bar code will be accepted.
Double Confirm:
If this option is enabled, the QS2500 will require a several
successful decodings to confirm the bar code data. Larger settings will
make misreadings less likely. If a double confirm is set, the multifield scan
function will be disabled.
Multifield Scan:
The QS2500 can be read many sets of bar code data on the
same scanning line at the same time, even if they are different kinds of bar
code symbology.