Product Reference Guide 27
Code 39
Read:
Format:
Checksum Verification:
The checksum is optional and presented as the sum
module 43 of the numerical value of the data digits.
Checksum Transmission:
When this option is enabled, the QS2500 will
transmit the checksum.
Maximum/Minimum Code Length:
Each symbology has own maximum and
minimum code length, which can be set to qualify data entry. The length
is defined as the actual bar code data length to be sent. Labels with lengths
below the minimum or above the maximum will be rejected. If the maxi-
mum and minimum code lengths are both set to zero, the global mini-
mum and maximum code length settings are in effect.
Truncate Leading/Ending:
Same as UPC-A. See page 19.
Truncate Leading Zero
Disable 00*
Enable 01
Expansion
Disable 00*
Enable 01
Option Bar Code Option Alphanumeric Entry
$$
Exi
t
Start “*” Data Digits (Variable) Checksum (Optional) End “*”
NOTE
Make sure that the minimum length setting is not greater than the maximum
length setting; otherwise, all the labels of the symbology will be unreadable.
You can set the same value for both minimum and maximum length to force
decoding of only bar codes of a certain length.