Page view 13
10 QS2500
Global Minimum/Maximum Code Length:
Global minimum and maximum
length can be set to qualify data entry. The length is defined as the actual
bar code data length to be sent. Labels with length exceeding these limits
will be rejected. Make sure that the minimum-length setting is no greater
than the maximum-length setting; otherwise, the labels of the symbology
will not be readable. In particular, you can set the same value for both
minimum and maximum lengths to force decoding of only fixed-length
bar codes. This setting has no effect on certain symbologies of fixed
length.
Option Bar Code Option Alphanumeric Entry
Scanning Mode
Good-read off 00
Momentary 01*
Alternate 02
Timeout off 03
Continue 04
Test only 05
Standby Duration
0–99 (sec.)
01–99
10*
Same Bar Code Delay Time
0–99 (10 msec.)
01–99
50*
Double Confirm
0–99
(0 = no double
confirm)
00–09
00*
Multifield Scan
Disable 00*
Enable 01
$
Start Program
$$