72191202 (05/2012) 0.0 METTLER TOLEDO DIVA Service Manual PSC 8500 Magellan Scanner
METTLER TOLEDO DIVA Service Manual 4 Mettler-Toledo (ChangZhou) Scale & System Ltd. Legal Metrology Declaration of Conformity Déclaration de c
METTLER TOLEDO DIVA Service Manual 5 Important notice for verified weighing instruments M M M M Weighing Instruments verified at the place of manufa
METTLER TOLEDO DIVA Service Manual 62 Installation 2.1 Precautions Before you install your DIVA scale, keep in mind the following factors, which migh
METTLER TOLEDO DIVA Service Manual 7 For Weigh Only Version: The Weigh Only version comes with a tower mount. Assemble the Weight Only tower as
METTLER TOLEDO DIVA Service Manual 82.5 Sealing After installation is complete, legal-for-trade applications require sealing so that the settings cann
METTLER TOLEDO DIVA Service Manual 9 For your notes:
METTLER TOLEDO DIVA Service Manual 103 Set-up and Calibration There are two types of setup modes. The first is called “Service Mode” and it allows
METTLER TOLEDO DIVA Service Manual 11 Price Computing Version Weigh Only Version You can press the Tare key to move to Grp 2, 3,
METTLER TOLEDO DIVA Service Manual 123.3 Set up Soft Switch and Default Table Group.Step Function Possible Selections Master Mode Access Group 1
METTLER TOLEDO DIVA Service Manual 13 Group 2 Press Zero to Enter Press Tare to go to Group 3 Group.Step Function Possible Selections Mast
METTLER TOLEDO DIVA Service Manual 14EXIT Press Zero to EnterPress Tare to go to Group 1 SAVE Save or abort setting SAVE – save all settings and r
METTLER TOLEDO DIVA Service Manual 15 3.4 Country Defaults PC WO WO WO WO WO WO WO WO WO WO WO WO WO WO WOFunction Germany/ France USA Austria Spain
METTLER TOLEDO DIVA Service Manual 163.5 GeoCal Country Codes Country Geo-Value Austria 18 Belgium 21 Bulgaria 16 Croatia 18 Czechia 20 Denmark 23
METTLER TOLEDO DIVA Service Manual 17 3.6 GeoCal USA State Location Codes State Code Alabama Birmingham & North South of Birmingham 13 12 Al
METTLER TOLEDO DIVA Service Manual 18
METTLER TOLEDO DIVA Service Manual 19 3.7 Calibration Note: These functions are directly related to the Weight & Measurement regulations in your
METTLER TOLEDO DIVA Service Manual 20Note: If the scale is unable to complete calibration it will display “E 20”. Cycle power to the scale and rest
METTLER TOLEDO DIVA Service Manual 21 4 Operating Instructions 4.1 Displays 72190532 72190533 72187467 72187468 72188
METTLER TOLEDO DIVA Service Manual 22 4.2 Keyboard Key Description Used to return the scale to gross zero. Tare key. 4.3 Cursors Cursor Descri
METTLER TOLEDO DIVA Service Manual 23 4.4 Operations 4.4.1 Weighing and Communication Place the item to be weighed on the platter, the weight will b
1 INTRODUCTIONThis publication is provided solely as a guide for individuals who have purchased the METTLER TOLEDO DIVA scale product. Information
METTLER TOLEDO DIVA Service Manual 245 Service and Maintenance This section provides information on servicing and maintaining the scale including:
METTLER TOLEDO DIVA Service Manual 25 5.2 Troubleshooting The following table lists error messages, descriptions, and corrective actions. Error Codes
METTLER TOLEDO DIVA Service Manual 26 Note: All other pins should not be connected. Should you need to construct your own communications cable. T
METTLER TOLEDO DIVA Service Manual 27 5.5 Parts and Descriptions General Exploded Diagram DIVA P2
METTLER TOLEDO DIVA Service Manual 28Diva P3 Consists of same parts as DIVA P2 with the exception of the parts labeled below
METTLER TOLEDO DIVA Service Manual 29 Note: Most parts are not available for individual replacement. This following chart and diagrams are onl
METTLER TOLEDO DIVA Service Manual 305.6 Replacement Parts Order Numbers Part Number Exploded ID Description Picture 72191106 23-30 SL DISP,W/LENS&
METTLER TOLEDO DIVA Service Manual 31 Part Number Exploded ID Description Picture 68001451 21 Security Label 72194083 Not Shown Mounting Screw
METTLER TOLEDO DIVA Service Manual 32Part Number Exploded ID Description Picture 71209952 34 PCB, FOUR LINE DISPLAY
METTLER TOLEDO DIVA Service Manual 33 6 Appendix 6.1 Protocols The numbers correspond to the number that will show up in the Soft Switch settings in
Precautions WARNING ONLY PERMIT QUALIFIED PERSONNEL TO SERVICE THIS EQUIPMENT. EXERCISE CARE WHEN MAKING CHECKS, TESTS AND ADJUSTMENTS THAT MUST BE
METTLER TOLEDO DIVA Service Manual 346.1.1 NCI – ECR 6.1.1.1 OVERVIEW The serial communications protocol is used to interface Weigh-Tronix/NCI PO
METTLER TOLEDO DIVA Service Manual 35 Name: Zero the scale Command: Z<CR> Response: Scale is zeroed, returns scale status. (
METTLER TOLEDO DIVA Service Manual 36 Weight Command: W This command causes the scale to return the displayed weight string in ECR format. The scale w
METTLER TOLEDO DIVA Service Manual 37 Scale Status Command: S There will be at least two status bytes. If bit 6 of the second status byte is set the
METTLER TOLEDO DIVA Service Manual 386.1.2 (Reserved) 6.1.3 8217 Mettler Toledo 6.1.3.1 Host Communications The 8217 scale acts as a peripheral dev
METTLER TOLEDO DIVA Service Manual 39 6.1.3.2 Command Descriptions ASCII Commands (* MUST BE UPPERCASE CHARACTERS ONLY.) *ASCII Command From Host Sc
METTLER TOLEDO DIVA Service Manual 406.1.3.3 Status Byte Format When the scale responds with STX?status byte CR , this indicates a status byte. The s
METTLER TOLEDO DIVA Service Manual 41 6.1.3.4 Confidence Test Status Byte Format When the scale responds with STX? status byte CR, after requesting
METTLER TOLEDO DIVA Service Manual 426.1.3.5 Tare Tare can be taken on an item two ways: Automatic or digital. REMOTE TARE The unknown weight of an o
METTLER TOLEDO DIVA Service Manual 43 6.1.4 8213 Mettler Toledo 6.1.4.1 Host Communications The 8217 scale acts as a peripheral device when connect
DIVA Service Manual 3 Contents 1 INTRODUCTION ...
METTLER TOLEDO DIVA Service Manual 446.1.4.2 Command Descriptions ASCII Commands (* MUST BE UPPERCASE CHARACTERS ONLY.) *ASCII Command From Host Scal
METTLER TOLEDO DIVA Service Manual 45 6.1.4.3 Status Byte Format When the scale responds with STX?status byte CR , this indicates a status byte. The
METTLER TOLEDO DIVA Service Manual 466.1.4.4 Confidence Test Status Byte Format When the scale responds with STX? status byte CR, after requesting a
METTLER TOLEDO DIVA Service Manual 47 6.1.5 EPOS 1 6.1.5.1 Data Format 2400 Baud (select 2400, 4800 or 9600) 7 data bits (select 7 or 8) Even parity
METTLER TOLEDO DIVA Service Manual 48 6.1.5.3 Command Flow ECR Scale COMMENTSENQ (05h) ACK (06h) Data Available. Errors could be: CAN - repeat we
METTLER TOLEDO DIVA Service Manual 49 6.1.6 EPOS 2 6.1.6.1 Data Format 2400 Baud (select 2400, 4800 or 9600) 7 data bits (select 7 or 8) Even parity
METTLER TOLEDO DIVA Service Manual 50 6.1.6.4 Command Flow ECR Scale COMMENTSENQ (05h) ACK (06h) Data Available. Errors could be: CAN - repeat we
METTLER TOLEDO DIVA Service Manual 51 6.1.7 (Reserved)
METTLER TOLEDO DIVA Service Manual 526.1.8 Dialog 06 With free programmable POS-Systems it is for a third party on principle possible, to manipulate p
METTLER TOLEDO DIVA Service Manual 53 6.1.8.3 Command Descriptions Records for Communications from a POS system to the Scale Record 01: Transmitti
6.1.11 ICL ...
METTLER TOLEDO DIVA Service Manual 54 Records for Communications from the Scale to a POS system Record 02: Result of weighing (answer to recor
METTLER TOLEDO DIVA Service Manual 55 6.1.8.4 Description of the Dialog A dialogue will always be initiated by the POS-system. Description of weig
METTLER TOLEDO DIVA Service Manual 56 6.1.8.5 Flow Chart EOT STX SATZ 03 ETXSTXSATZ 04 ETXETXSTX SATZ 05 ETXSTX SATZ 10 ETXSTX SATZ 20 ETXENQSTX
METTLER TOLEDO DIVA Service Manual 57 6.1.9 Dialog 04 / 02 Note: To use Dialog 04, select this protocol but set the baud rate to 4800, for Dialog
METTLER TOLEDO DIVA Service Manual 58 6.1.9.3 Command Descriptions POS System Communications to a Scale Setting number 01 - Basic Price EOT STX 3
METTLER TOLEDO DIVA Service Manual 59 Scale Communications to a POS System Setting number 02: Weight, Price, and Total Price STX 30h 32h ESC
METTLER TOLEDO DIVA Service Manual 60 6.1.10 Extended Dialog 06 The Extended Dialog 06 protocol is for use with communication between the DIVA and the
METTLER TOLEDO DIVA Service Manual 61 6.1.11 ICL 6.1.11.1 Data Format 9600 Baud (select 2400, 4800 or 9600) 7 data bits (select 7 or 8) Even parity
METTLER TOLEDO DIVA Service Manual 62 6.1.11.4 Command Flow ECR Scale COMMENTSENQ (05h) ACK (06h) Data Available. Errors could be: CAN - repeat w
METTLER TOLEDO DIVA Service Manual 63 6.1.12 Shekel (WO) 6.1.12.1 Command Flow ECR Scale Comment S<CR><LF> S_XXXXXXXXXX_g_<CR&
1 1 Introduction The DIVA is designed to mount on the PSC 8500 Scanner and communicate with ECR and POS systems for weighing needs. 1.1 Reliability T
METTLER TOLEDO DIVA Service Manual 646.1.13 RIVA 5462 (WO) 6.1.13.1 Data Format 2400 Baud 7 data bits Odd parity 2 stop bit Weight request: <Stx
METTLER TOLEDO DIVA Service Manual 65 6.1.14 IP3 (PC) 6.1.14.1 Data Format 9600 Baud (typical) 7 data bits (typical) Even parity (typical) 1 stop bit
METTLER TOLEDO DIVA Service Manual 66 6.1.14.2 Command Descriptions ECR Time out Scale COMMENTS STX (02h) 500ms ACK (06h) @ (40h) 1 (31h
METTLER TOLEDO DIVA Service Manual 67 6.1.15 (Reserved)
METTLER TOLEDO DIVA Service Manual 68 METTLER TOLEDO 1900 Polaris Parkway Columbus, Ohio 43420-2020 P/N: 72191204 ME
METTLER TOLEDO DIVA Service Manual 21.3 Physical Dimensions The dimensions of the scale with tower are as follows:
METTLER TOLEDO DIVA Service Manual 3 1.4 Power Requirements Two different power options exist: 1. If the scanner is equipped for use with MT weigh