PSC Magellan 8500 Service Manual Page 68

  • Download
  • Add to my manuals
  • Print
  • Page
    / 74
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 67
METTLER TOLEDO
DIVA Service Manual 62
6.1.11.4 Command Flow
ECR Scale COMMENTS
ENQ (05h)
ACK (06h)
Data Available.
Errors could be:
CAN - repeat weighing
NAK - no acknowledgement
NUL - no data available
DC1 (11h)
Data Request
Errors could be:
NAK – no acknowledgement
STX ID W5W4W3W2W1 BCC ETX Transmitted Data
STX ID W5W4W3W2W1 BCC ETX
Confirm Data
Errors could be:
ACK – Data not confirmed
NAK – receive error or scale
error detected.
CR (0dh)
Data confirmed, CAN response to
ENQ is activated until current
transaction is cleared.
Note: The POS can request and receive additional weight data from the scale before returning
the verification weight but the verification weight must equal the last weight sent by the scale.
Note: Spaces depicted in the description above are only used for ease of reading. No space
characters are used unless the BCC result yields the space character.