METTLER TOLEDO
DIVA Service Manual 37
Scale Status Command: S
There will be at least two status bytes. If bit 6 of the second status byte is set then there will be
a third byte. Bit 6 of each successive byte will indicate whether or not another status byte
follows. The bit will be clear (0) in the last status byte. At this time only the first three bytes are
defined. Others may be added in the future. Bit 0 is the least significant bit in the byte while bit
7 is the most significant bit.
The status bits are defined as follows:
Bit Status Byte 1 Status Byte 2 Status Byte 3 Status Byte 4
0
1 = Scale in motion
0 = Stable
1 = Under capacity
0 = Not under capacity
00 = Low range
01 = (undefined)
10 = (undefined)
11 = High range
1 = Weight Change
0 = No Change
1
1 = Scale at zero
0 = Not at zero
1 = Over capacity
0 = Not over capacity
1 = Zero Detected
0 = No Zero Seen
2
1 = RAM error
0 = RAM okay
1 = ROM error
0 = Calibration okay
1 = Net weight
0 = Gross weight
1 = Metric
0 = English
3
1 = EEPROM error
0 = EEPROM okay
1 = Faulty calibration
0 = Calibration okay
Initial zero error Unused
4
Always 1 Always 1 Always 1 Always 1
5
Always 1 Always 1 Always 1 Always 1
6
Always 0
1 = Byte follows
0 = Last byte
1 = Byte follows
0 = Last byte
1 = Byte follows
0 = Last byte
7 Parity Parity Parity Parity